Schedule 80 as is the case in all three strength measurements is much stronger than schedule 40 pvc.
Pvc schedule 80 pressure rating.
Schedule 80 fittings schedule 80 and schedule 40 tapered socket dimensions pvc schedule 80 astm d 2467 pvc schedule 40 astm d 2466 american national standard taper pipe threads npt ansi asme b1 20 1 astm d 2467 astm f 1498 effective nominal thread threads pitch of size length l per inch thread p 1 2 0 533714 0 07143 3.
Pressure de rating at elevated temperatures the pressure ratings above are for water at 73 degrees fahrenheit.
The chart below will illustrate the pressure derating of pvc as temperatures increase.
This makes it perfect for mechanical and synthetic applications.
All compound components shall be listed with nsf and meet the requirements of nsf ansi standard 61 g as suitable for potable water and is considered lead free.
Minimum tensile strength 60 ksi 60000 psi.
Schedule 80 pipe nipple pressure rating has thicker dividers and can with stand higher psi pounds per square inch.
This table defines the maximum pressure rating for the specified industry standard pipes schedule 160 schedule 40 and schedule 80.
Suitable for oil free air handling to 25 psi not for distribution of compressed air or gas page 336 due to material cost variations prices subject to change.
For pvc fitting schedule 40 and pvc fittings schedule 80 the optimal temperature at which pvc can operate at the highest psi would be 73 degrees fahrenheit.
To give you a thought of the size contrast 1 plan 40 pvc pipe has a 133 least divider and 450 psi while plan 80 has a 179 least divider and 630 psi.
Schedule 80 pvc technical information schedule 80 pvc pipe dimensions pressure ratings made in the u s a.
Max pressure 73 x derating factor schedule 80 pipe pvc pipe operating temp f de rating factor 73 1 00 80 0 88 90 0 75 100 0 62 110 0 51 120 0 40 130 0 31 140.
Schedule 80 pvc technical information schedule 80 pvc pipe dimensions pressure ratings made in the u s a.
As with burst pressure the amount of collapse pressure pvc pipe can withstand decreases as size increases.
Astm d2467 04e1 standard specification for poly vinyl chloride pvc plastic pipe fittings schedule 80 1 psi lb in 2 6 894 8 pa n m 2 1 inch 25 4 mm.
The speci fi ed derating factors for pvc are suitable for pipe conveying water at.
As the temperature of the pvc increases the pressure that the pvc can withstand will decrease.
It can withstand a substantial amount of exterior pressure.
Api 5l carbon steel pipe and a 106 a 53 a333 a334.
To calculate elevated temperature rating use the following formula.